The DS-5 is essentially a DS-2B fitted with a dual 30A @ 240 VAC load control contact set. It is primarily designed for larger satellite antenna/broadcast tower deicing and pavement snow melting applications. Specifically, any job that a DS-2B can perform a DS-5 can perform with double the load handling capability.
The unit is housed in a two gang PVC enclosure. The overall dimensions of the DS-5 are 4¾"(120) x 7"(178) x 2¾"(70). The unit weighs 2 pounds. The user may access all electronics by removing the four front cover screws.
Wiring is performed by terminating your existing wiring to the pre-installed pigtails (see below.) The DS-5 is mounted by either attaching the mounting hub to a rigid ½" or ¾" conduit or by installing screws through the four mounting tabs provided.
The DS-5 can be powered from either a 100-120 VAC or 200-240 VAC 50/60Hz source. Peak power consumption is 15 watts. Voltage selection is performed by installing provided jumpers onto the printed circuit board. The unit provides a dual 240VAC @ 30A normally open load contact set. This contact set is paralleled with a low power contact set to provide remote activation monitoring. Operational temperature range is -40oC to +85oC.
An environmentally sealed control switch is provided. The "Manual On" function activates the controlled equipment for testing and special operational conditions. The "Automatic" position allows the DS-5 to handle all detections and control. The "Standby/Reset" position disables triggering and can also be used to clear the delay off timer (see below) from true or test activation. Remote control and monitor up to 1000 feet away is also available when the optional C/M cable listed is installed. The DS-5 is also compatible with the DP-7B, DP-7EX, and CDP-2 remote control/status panels.
A new feature has been added to the DS-5. If the switch is placed in "Manual On" for less than 2 seconds, then switched back to "Automatic" the controller will execute one delay off cycle. The delay off cycle is determined by the DEL switch setting and the DEL adjustment, i.e., 2 minutes in "sensor" mode, 30-90 minutes in "controller" mode. This can be used to clear surfaces with a frost or hail buildup without the danger of leaving the system in a continuous "Manual On" condition. "Standby/Reset" can still be used to clear this delay off cycle.
The table below outlines the operating modes for the DS-5. Trigger Temperature (TT) is adjustable from 34oF-44oF using an on-board control. When ambient air temperature (AT) is below this trigger point precipitation is assumed to be snow or freezing rain. When above the trigger point, precipitation is assumed to be rain.
"Delay Off" refers to the internal drying cycle timer of the DS-5. The timer is used to allow the DS-5 to dry the heated surface through evaporation once precipitation has stopped. The drying cycle reduces the chance that moisture left behind by the melting process will refreeze into ice. This timer is restarted by each precipitation detection. Therefore, the DS-5 will continue to operate as long as precipitation and trigger temperature is detected, then for the "Delay Off" time once rain or snow stops. It is assumed that, when operating as a sensor, the DS-5 is supplying an activation signal to an external control system. All "sensor" modes provide a minimum 2 minute closure to reducing cycling of the external controller. When in a "controller" mode the Delay Off time can be adjusted from 30-90 minutes. Proper adjustment assures drying without excessive runtime.
The Low Temperature Cutoff (LTC) option is typically used on deicing or snow melting systems with limited output capacity. If selected, the sensor will not trigger if precipitation is detected below 15oF. However, if the deicing system has been activated, precipitation continues, and the ambient temperature drops below 15oF, LTC will be ignored. This assures that water left behind on the surface during the heating cycle will not immediately refreeze into ice as a result of deactivating the deicing system.
| Function | Ambient Temp (AT) | Delay Off | Suggested Application |
| Snow sensor w\o LTC | AT < TT | 2 Min | Snow and ice alert, Sensor for external deice/snow melt controller (unlimited heat) |
| Snow sensor w\LTC | TT>AT>15oF | 2 Min | Sensor for external deice/snow melt controller (limited heat) |
| Snow controller w\o LTC | AT < TT | 30-90 Min | Stand-alone controller for satellite antenna/tower deicing and electric/hydronic snow melting |
| Snow controller w\LTC | TT>AT>15oF | 30-90 Min | Stand-alone controller for satellite antenna/tower deicing and electric/hydronic snow melting |
| Precipitation sensor | Not Used | 2 Min | Snow, ice, and rain alert, Ku band rain and snow diversion |
| Precipitation controller | Not Used | 30-90 Min | Snow, ice, and rain alert, Ku band rain and snow diversion |
| Rain sensor | AT>TT | 2 Min | Rain alert, Ku band rain diversion |
| Rain controller | AT>TT | 30-90 Min | Ku band rain diversion |
Download or view the DS-5
Installation Manual in PDF.
![]()
| DS-5 Specifications | |
| Dimensions | 4¾"(120) x 7"(178) x 2¾"(70) |
| Weight | 2 Lbs. (0.9 Kg) |
| Operating Temperature | -40oF to +185oF (-40oC to +85oC) |
| Enclosure Rating | NEMA 3R |
| Supply Power | 100-120VAC/200-240VAC Field Selectable 15W maximum |
| Trigger Temperature | 34oF-44oF (1.1oC-6.6oC) Field Selectable |
| Delay Off (Sensor) | 2 Minutes |
| Delay Off (Controller) | 30-90 Minutes Field Selectable |
| Load Contact Capacity | 2 x 30A @ 240 VAC/100,000 operations minimum at full load |
| Monitor Contact Capacity | 24 VDC/VAC 400mA 10W total |
![]()
DS-5
Sensor
Controller Part Numbers
Typical leadtime for a DS-5 is stock to 1 week
| Type | Conduit Hub | Power Pigtail | Load Pigtail #1 | Load Pigtail #2 | ||||
| DS | - | 5 | - | XXX | - | X | X | X |
| | | | | | | | | |||||
| 500 - 1/2" NPT | 1 - #14 AWG Black, White, Green | 1 - #10 AWG Yellow | 1 - #10 AWG Yellow | |||||
| 750 - 3/4" NPT | 2 - #14 AWG Black, Red, Green | 2 - #10 AWG Red | 2 - #10 AWG Red | |||||
| 3 - #14 AWG Blue, Brown, Green/Yellow |
For example:
A DS-5 with a 1/2" conduit hub, 240VAC power pigtails, and yellow and red
load pigtails would be a DS-5-500-212
Power and load pigtails are MTW UL 1015 105oC 600V and are 18" in length from base of conduit hub.
|
Part Number |
Description |
| DS-5-xxx-xxx | DS-5 with power and 2 load pigtail sets |
| CS-1 | Control/Monitor Cable, 18", #22 AWG, 5 Conductor 300V |
Replacement Parts
|
Part Number |
Description |
| MG-1 | Precipitation Grid Replacement Kit with Sealing Washer/Teflon Tape |
| RP-1 | Thermal Probe Assembly |
| RP-3 | Fuse Kit, ½A 250Vac 2AG (5) |
| RP-4 | Override Switch w\Boot,Cable |
| RP-5-5 | Front Cover w\Label, Gasket, 4 Cover Screws |
| RP-8 | Voltage Selection Jumpers (2) |
Please call for current pricing and leadtime.
Purchase orders accepted with approved credit. Terms are net 30 days.
Shipping and applicable VAT, customs charges, brokerage fees, and duties are not included.

Visa
and MasterCard accepted.
2% surcharge on all international
and US government credit card orders.
Attention
Canadian Customers!
![]()
Need Remote Control/Monitor Capabilities?
Take a look at the
affordable remote extension for your DS Series sensors and
controllers.
The DP-7 Family of Control/Status
Panels
![]()
For More Information, Contact
Automated Systems
Engineering, Inc.
2519 E Saint Vrain Street
Colorado Springs, Colorado, USA 80909
Phone: 719-599-7477 FAX: 719-599-7482
info@goase.com
![]()
Home
DS Overview Operation
Features Applications
DS-2B DS-224 DS-4
DS-5 DS-6 DS-8
DS-824
DP-7 CDP-2 Cable
Sets Parts
Manuals Troubleshooting
Price List
Best if viewed at 800 x 600
This site is copyright 1998-2008 by Automated Systems Engineering, Inc.
Comments about the website? Please contact webmaster@goase.com
Last Update: 04/11/08